CN-1002 Medical Ventilator

Main technical parameters
Display Colored 5.7” LCD, touch screen setting, big font display, free changeable angles of views
Various ventilation modes SIPPV、SIMV、PCV、SPONT、MANUAL、CPAP
Ventilation parameters PEEP、SIGH、IRV、Inspiratory platform

Main technical parameters

Display Colored 5.7” LCD, touch screen setting, big font display, free changeable angles of views  

Various ventilation modes:       SIPPVSIMVPCVSPONTMANUALCPAP

Ventilation parameters:          PEEPSIGHIRVInspiratory platform

Tidal Volume :                 50-1500 mL

Rate  :                       199bpm

SIMVrate:                     220bpm

I:E  :                        4:11:8  

Trigger sensitivity :            -1.01.0kPa    

PEEP :                       025cmH2O  

Pressure control :              350cmH2O  

SIGH :                 1.5 times the inspiratory time (60 ~ 120 times adjustable)      

Inspiratory platform :           050%   

Oxygen concentration :         48%100%   

Pressure limit  :              560cmH2O  

Parameters for ventilation monitoring :    tidal volume, ventilation volume, IPPV rate, total respiratory rate, peak pressure of airway, pressure - time waveform, flow rate - time waveform, inspiratory trigger pressure, Inspiratory platform, Oxygen concentration, battery capacity


Safety alarm system    

Airway pressure alarm  :               upper limit setting range   0.36.0 kPa

lower limit setting range    0.25.0 kPa

Per-minute ventilation volume alarm :     upper limit setting range 3.030L/min  

lower limit setting range  1.010L/min

Vt alarm :                           upper limit setting range 102000ml    

lower limit setting range  01800 ml     

Sustained high-pressure alarm :      it will give alarm when stress have consistently been higher than 2.5 kPa                                                   

Suffocation alarm :                it will give sound and light alarm if there is no tidal volume input for 15 seconds     

Power failure alarm  :      

Power :                   AC 220V±10%     50Hz±1Hz

                               UPS, Storage battery    

Battery under-voltage alarm

Power loss alarm  

Intubation off alarm     