Features:
Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data;
Build-in rechargeable Li-battery, up to 15 hours running time, support AC and DC power;
Adjustable audible and visual alarms, and sensor off alarm;
Long time monitoring and sleeping monitoring;
Easy to carry, suitable for ambulance center, has the stand for fixing;
ETCO2, FiCO2 and RR are optional.
Advantage:
Storage and review data up to 3888 groups via Trend Graph and Trend List.
USB data upload
Bluetooth to connect with Android software;
Big font screen interface is easy to observe;
Back light can be adjusted;
Free advanced software are all standard on free(VSDV software for download the storage data; Guardian software for transmitting the real-time data and storage all data and waveform; Healthaids software for Android mobile)
Specification:
1. General Specifications:
Size: 209mm×104mm×47.5mm
Net Weight: 655g
Display Specification
Measurement Display: color TFT- LCD/touch screen
Power Supply Indicator: Dual-color LED (red/green)
Charging indicator: A green LED
2. Power Supply
AC Power Adaptor
Input: 100~240VAC, 50/60Hz, 0.7A
Output: DC 5V, 1.5A
Battery
Li-ion rechargeable battery, 3.7V/7200mAH
Operating Time: 15 hours with full battery capacity.
(Condition: 25℃, NIBP working period is 15 minutes)
Recharge Time: 10 hours.
3. Environment
Temperature
Working:0C~45C
Transport and Storage: -25C~85C
Humidity
Working:30% ~85 %
Transport and Storage: 30% ~95 % (no condensation)
4. Monitoring Parameter
ECG
Input:5- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III, avR,avL,avF,C
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation
Heart Rate
Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm
SpO2
SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution: 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MAP value measured using this device is equal to that measured using blood pressure measurement device.
Temperature
Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0℃~50℃
Accuracy: ±0.1℃
EtCO2(Optional)
Measuring Range: 0~150mmHg
Resolution: 1 mmHg
Accuracy: ±2mmHg@< 5.0% CO2
Respiration Rate(Optional)
Measuring Range: 0~120rpm
Resolution: 1rpm
Accuracy: ±1rpm
5. Storage and Review
Maximum Data Quantity: 3888 groups
Maximum Trend Time: Continuous 129.6 hours
Standard accessories
Standard Packing List | |
Color palm patient monitor main unit | 1 pc |
5-lead ECG cable ( include surface TEMP probe) | 1pc |
Adult finger SpO2 sensor | 1 pc |
Adult NIBP cuff | 1 pc |
NIBP extension tube | 1 pc |
USB cable | 1 pc |
AC power adapter | 1 pc |
The operator’s manual | 1 pc |
Selectable Accessory | |
Pediatric NIBP cuff | |
Pediatric finger Spo2 sensor | |
Neonatal wrap SpO2 sensor | |
EtCO2 module(optional) | 1 pc |
Drying tube(optional) | 2 pcs |
Sampling tube(optional) | 1 pc |
Nasal tube(optional) | 1 pc |
3-way elbow(optional) | 1 pc |