Welcome: chuangen medical
Language: Chinese ∷  English
chuangen.medical@aliyun.com +86 0556-5222292

CN-F100B Automatic Dialysate Stirring Machine

1. The overall design meets the requirements of the China Health Ministry and dialysis guiding norms;
2. Bucket material is medical polyethylene, light weight &tough, impact-resistant, corrosion-resistant, long service life;
3. The whole machine has no residual dead ends, easy to wash;
4. The machine design is reasonably easy to operate;
5. Characterized by instantaneous mixing, the dialysate is stable, less volatile; after mixing.
6. The mixing time is short and can be fully mixed, no residual bubbles in the mixture;
7. No fish eye caking and any other type of blocking phenomenon;
8. The quantitative perfusion, to make the pharmacy to meet the different needs of patients.

A/B Powder

图片2.png

Powder A

Composition: Sodium chloride 1053.38 g, Potassium chloride 32.62g, Calcium chloride 38.59g, Magnesium chloride 17.79g, Acetic acid 30.05g.

 

Powder B

Composition: sodium bicarbonate

Application: Acute and chronic renal failure and other blood purification treatment.

 

Parameters:

The concentrate B includes electrolyte density of sodium bicarbonate: 8.4%

The concentrate B includes density of bicarbonate ion: 35 mmol/L.

 

The density of ion for electrolyte of the dialysate (mmol/L) and PH.

 

Na+

K+

Ca2+

Mg2+

Cl-

CH3COO

HCO3-

PH

138.0

2.5

1.5

0.5

109.5

3.0

35.0

7.0-7.6

Blood Line Tube

图片3.png

- Medical grade PVC tubing minimizes side effect to health.
- All components are manufactured in original and monitored consistently.
- A variety of models are available for most brands of hemodialysis machines in operation worldwide; customized blood lines are available on request.


Fistula Needle

图片4.png

- Ultra thin wall and siliconized for smoother penetration.
- Special process on blade reduces pain and skin damage for smoother penetration.
- Medical grade PVC tubing minimize side effect to health.
- Sterilization: E.O.gas.and gamma ray.


Dialyzer

Low flux, wet membrane

图片5.png

Function

Type

REXEED-13LC

REXEED-15LC

Blood flow ml/min

200

300

200

300

Clearance Rate

ml/min

Urea

192

255

195

265

Creatinine

186

241

191

251

Phosphate

147

175

157

191

vitamin B12

88

93

97

108

Ultrafiltration Rate

ml/mmhg/hr

9

8

12

10

Effective aream2

1.3

1.5

 

ConditionClearance rateQd=500ml/min,Qf=0ml/min

Ultrafiltration RateHaematocrit is 32%±2%Protein density is 60g/L±5gTMP=50mmHg (Accoring to the test record for Cow.)

Design demention