1. The overall design meets the requirements of the China Health Ministry and dialysis guiding norms;
2. Bucket material is medical polyethylene, light weight &tough, impact-resistant, corrosion-resistant, long service life;
3. The whole machine has no residual dead ends, easy to wash;
4. The machine design is reasonably easy to operate;
5. Characterized by instantaneous mixing, the dialysate is stable, less volatile; after mixing.
6. The mixing time is short and can be fully mixed, no residual bubbles in the mixture;
7. No fish eye caking and any other type of blocking phenomenon;
8. The quantitative perfusion, to make the pharmacy to meet the different needs of patients.
A/B Powder
Powder A
Composition: Sodium chloride 1053.38 g, Potassium chloride 32.62g, Calcium chloride 38.59g, Magnesium chloride 17.79g, Acetic acid 30.05g.
Powder B
Composition: sodium bicarbonate
Application: Acute and chronic renal failure and other blood purification treatment.
Parameters:
The concentrate B includes electrolyte density of sodium bicarbonate: 8.4%
The concentrate B includes density of bicarbonate ion: 35 mmol/L.
The density of ion for electrolyte of the dialysate (mmol/L) and PH.
Na+ | K+ | Ca2+ | Mg2+ | Cl- | CH3COO | HCO3- | PH |
138.0 | 2.5 | 1.5 | 0.5 | 109.5 | 3.0 | 35.0 | 7.0-7.6 |
Blood Line Tube
- Medical grade PVC tubing minimizes side effect to health.
- All components are manufactured in original and monitored consistently.
- A variety of models are available for most brands of hemodialysis machines in operation worldwide; customized blood lines are available on request.
Fistula Needle
- Ultra thin wall and siliconized for smoother penetration.
- Special process on blade reduces pain and skin damage for smoother penetration.
- Medical grade PVC tubing minimize side effect to health.
- Sterilization: E.O.gas.and gamma ray.
Dialyzer
Low flux, wet membrane
Function:
Type | REXEED-13LC | REXEED-15LC | |||
Blood flow (ml/min) | 200 | 300 | 200 | 300 | |
Clearance Rate (ml/min) | Urea | 192 | 255 | 195 | 265 |
Creatinine | 186 | 241 | 191 | 251 | |
Phosphate | 147 | 175 | 157 | 191 | |
vitamin B12 | 88 | 93 | 97 | 108 | |
Ultrafiltration Rate (ml/mmhg/hr) | 9 | 8 | 12 | 10 | |
Effective area(m2) | 1.3 | 1.5 |
Condition:Clearance rate:Qd=500ml/min,Qf=0ml/min
Ultrafiltration Rate:Haematocrit is 32%±2%,Protein density is 60g/L±5g,TMP=50mmHg (Accoring to the test record for Cow.)