Welcome: chuangen medical
Language: Chinese ∷  English
chuangen.medical@aliyun.com +86 0556-5222292

CN-SNP9000L 8.4 inch Multi-parameter Bedside Monitor

Features &Benefits:
8.4” color TFT display, high resolution
Integrated para board: ECG, NIBP, SpO2 board;
Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.
Real time S-T segment analysis, and ARR analysis;
SpO2 Pitch Tone Variation and Drug Dose Calculation;
Parameter waveform and characters color selectable
Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
Standby mode for Energy saving and suspend monitoring;
7-lead ECG waveforms display in phase;
Capture dynamic waveforms;
Built-in rechargeable lithium battery, and battery volume checking,
AC power checking
Efficient resistance to interference of defibrillator and HF knife;
SINNOR F-6 SpO2 technology, VS NELLCOR accuracy;
Networking capacity and TCP/IP networking platform enable abundant future upgrade
Time delay switch-off function keep the monitor data restart monitor;
Complete and flexible mounting solution for transportation and in-patient monitoring

Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.
Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,

Performance Specifications

Display:     8.4”color TFT

Rolling and refreshing waveform display

Resolution: 800×600

Multi display selectable including:

Large-font display

Trend coexist display

OxyCRG dynamic view display.

Bed-to-bed view display

Trace:             9 waveforms(7 ECG, 1 SPO2 and 1 RESP)

Sweep speed:12.5mm/s,25mm/s,50mm/s

Indicator:          Power/battery indicator light

QRS beep and alarm sound

Battery:           Rechargeable lead acid cell, 12v/4AH

Max.24 hour for charging, 4 hours for continue working

Trend:             Parameter graphic and tabular trends:

5s/piece,8 hours;

1min/piece,168 hours(24hour×7days)

5min/piece,1000 hours.

 

Storage:           NIBP: 1000 groups

Alarm: 200 groups

Full disclosure waveforms: 3600S

SD card external storage

Alarm:         User-adjustable High, Medium and Low limits 3-level

 Audible and visual alarm

Networking:        Connected to central monitoring system

TCP/IP netting platform

Recorder:         Build-in, thermal array

Plethysmogram caveform:2 channels

Record mode: manual, on alarm, time-defined

Recording width: 50mm

Printing speed: 50mm/s

Recording type:    Frozen waveform record

NIBP recall record

Trend table record

Alarm record

Fixed -time record

 

Standard parameter:

ECG:

 

Lead mode:    5 –lead(R,L,F,N,C)

Lead selection :   I,II,III,avR,avL,avF,V

Waveform:       3 and 7 channel selectable

Gain selection:   0.5mm/mv,1mm/mv,2mm/mv

Sweep speed:   12.5mm/s;25mm/s;50mm/s

Heart rate range:     Adult: 15~300bpm;

Neonate/pediatric:15~350bpm

Accuracy:    +1bpm or +1%,whichecer is greater

Resolution:       1bpm

Filter:     surgery mode:1~20Hz

monitor model:0.5~40Hz

Diagnostic mode:0.05~130Hz

Scaling signal:   1mv,+3%

Protection:       withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation

Alarm range:   15~350bpm

S-T segment detecton:  

Measurement range:  2.0mV~+2.0mV                         

 

 Alarm Range:         -2.0mV~ +2.0mV

Accuracy:            -0.8mV ~+0.8Mv

Error:               +0.02Mv

 

Arrhythmia analysis: YES

 

SPO2

Measurement range:        0~100%

Resolution:                1%

Accuracy:                 +2%(70-100%);0-69% unspecified

Alarm range               0~100%

Pluse Rate:                

range:        20~300bpm

Resolution:   1bpm

Error:        +1bpm or +2%,whichever is greater

 

NIBP

Method:                   Digital Automatic oscillometric

Operation mode :            Manual/Automatic/continuous

Auto measurement time:      Adjustable(1~480min)

Measurement Unit:          mmHg/Kpa selectable

Measurement types:         Systolic, Diastolic, Mean  

Measurement tange:

Range of Systolic pressure:    Adult: 40~270mmHg

Pediatric: 40~220mmHg

Neonate: 40~135mmHg

Range of mean pressure:      Adult: 20~235mmHg

Pediatric: 20~165mmHg

Neonate: 20~110mmHg

Range of diastolic pressure:   Adult: 10~215mmHg

Pediatric: 10~150mmHg

Neonate :10~100mmHg

Over-pressure protection:     Double safety protection

Resolution:                 1 mmHg

Alarm:                    Systolic.Diastolic,Mean

 

 

RESPIRATION

Method:                     Thoracic impedance

Measurement range:           Adult:7~120rpm;

Neonate/Pediatric:7~150rpm

Apnea alarm:                 YES,10~40s

Resolution:                   1rpm

Accuracy:                    +2rpm

 

 

TEMPERATURE

Compatible probe:             YSI or CYF

Measurement range:           5~50

Resolution :                   0.1

Accuracy:                    +0.1

Refreshing time:               about 1

Average measuring time:        <10s

 

FHR

Transducer:   Multi-crystal, Pulsed Doppler

Measurement range:  50~210 BPM

Working frequency:   1 MHz

Strength:   <5mW/cm2

Signal processing:  

special DSP system and modern recognization.

Resolution:   1BPM

Accuracy:    ±1BPM

Alarm Range:  High: 160,170,180,190 BPM,

Low: 100,110,120 BPM

 

FM

Manual button marking,

automatic FM identifying function

 

TOCO Measuring

Transducer:  External pressure transducer

Measurement range:  0~100 units

Resolution:  1rpm

Accuracy:  ±2 rpm

 

 

IBP

Channel: 2 channels

Range: 50-300mmHg

Resolution: 1mmHg

Accuracy: ±4mmHg(±4%)

Unit: mmHg, Kpa

Converter Sensitivity: 5mV/V/mmHg

Transducer sites: ART/PA/CVP/LAP/RAP/ICP

 

EtCO2( Sidertream CO2)

Measurement range:   0~99mmHg

Accuracy:   +2mmHg (0~40mmHg)

Sampling Range:   100ml/min

Sampling rate accuracy:   15%

Respiration rate:   0~120rmp

Respiration accuracy:  +2rmp (0~70rmp)

+5rmp (>70rmp)

Respiration time:   <240msec (10% to 90%)

Delay time:  <2s

 

EtCO2 (mainstreaam CO2)

Method:   Infrared Spectrum

Range:   0.0-10% (0~76%)

Resolution:   1mmHg (0.1%)

Accuracy:   5%(±4.0 mmHg)

         Or10%(of Readings)

 

Recorder:     

Build-in, thermal array

Plethysmogram caveform:2 channels

Record mode: manual, on alarm, time-defined

Recording width: 50mm

Printing speed: 50mm/s

Recording type:  Frozen waveform record

NIBP recall record

Trend table record

Alarm record

Fixed -time record

 

Miscellaneous

Satety:              

Safety level: Class I, type CF

 

Dimendion and Weight

Dimendion:      28*42*48cm         

G.Weight:        <6.5KS

 

Operation Environment

Temperature:    Working 0~+40

Transportation and storage –20~+60

Humidity:       working≤85%

Transportation and storage≤93%

Power:          AC 100-240,50/60Hz

Patient range:    Neonate,pediatric,and adult patients

 

Accessories supplies

(1) 5 lead ECG cable  

(2) 1 spo2 probes  

(3) 1 NIBP prbe  

(4) 1 temp probe

(5)1 ground connecting liner  

(6) Chest electrode (10pcs/set)


INQUIRY

CATEGORIES

CONTACT US

Contact: Katrina Yao

Phone: +0086 18255652021

Tel: +86 0556-5222292

Email: chuangen.medical@aliyun.com

Add: Area C, Huamao 1958 Project, No.80, South Fangzhi Road, Daguan District, Anqing, Anhui, China.