CN-8500 High Frequency Digital Radiography System (500mA 55kw,Flat Panel Detector)

TECHNICAL PARAMETERS
1. GENERAL ELECTRICAL PERFORMANCE
Maximum output power: 55kW
Inverter frequency: 60kHz
Tube voltage for radiography: 40~150kV
Tube current for radiography: 10mA~500mA
Exposure time: 0.001s~12.5s
mAs for radiography: 0.1~630mAs
Power supply: 380 V, 50 Hz
Shortest time for AEC: 5ms

TECHNICAL PARAMETERS

1. GENERAL ELECTRICAL PERFORMANCE

Maximum output power: 55kW

Inverter frequency: 60kHz

Tube voltage for radiography: 40~150kV

Tube current for radiography: 10mA~500mA

Exposure time: 0.001s~12.5s

mAs for radiography: 0.1630mAs

Power supply: 380 V, 50 Hz

Shortest time for AEC: 5ms

2. X-RAY TUBE ASSEMBLY

Focus: 0.6/1.2mm

Power for focuses: 27kW/75kW     

Anode thermal capacity: 210kJ 300kHU

Anode target angel: 12°

Anode rotating speed: 9700rpm

Tube thermal capacity: 900kJ

3. DIGITAL DETECTOR

Detector type: flat panel

Scintillating medium type: cesium iodide

Field: 17″×17″

Pixel matrix: 33k

Pixel size: 143μm

Limited spatial resolution: 3.6Lp/mm

Shortest imaging time ≤ 12s

HJHZ3J{I~M6W(VCE_Q~99FX.png 

 

 

 

 

 

 

4. IMAGING WORKSTATION

4.1Acquisition Module

Gigabit Ethernet acquisition, enhanced image adaptive processing

4.2 The image processing module   

Tissue Equalization, W / L adjustment, points of interest, a negative phase, noise reduction, smoothing, sharpening; single window, double window, four-window, multi-window, move, right-handed 90-degree, 90-degree left-handed, horizontal mirror, vertical mirror magnifying glass, image scaling, image restoration, layer information, text annotation, image annotation, length measurement curve measurement, angle measurement, rectangular length, area of a rectangle, ellipse length, oval area, polygon area, measuring edit measuring deleted.

4.3 The image information management

DICOM image storage, DICOM image read, DICOM image printing, DICOM image transmission

[JVSUQR]B@T0[JOV`G_898C.png

5. U-ARM AND PILLAR SYSTEM

5.1 U-arm vertical lift distance ≥1250 mm

5.2 Focus-screen distance adjustment range 1000mm1800mm

5.3 U-arm rotation range: -40°—130°

 

Y@XKMPT)@BZ{OR)$$VAAU]W.pngIJO%TWR86%3~8([JDLK{OW6.png 

 

 

 

 

 

 

STANDARD CONFIGURATION

1. High quality, high frequency, high voltage generator device

2. X-ray tube assembly

3. 17″×17″flat panel detector

4. High-performance image processing workstation

5. 19 "grayscale medical LCD monitor

6. Color graphical LCD touch control device

7. Electrical box

8. New U-arm main frame

9. With a light source symmetrical adjustable collimator

10. AEC automatic exposure ionization chamber

 

CHARACTERISTICS

1. Cesium iodide flat panel detector, adopting advanced manufacturer art, which is of very stable performance.

2. The effective detecting area is of 17”×17”, it can satisfy radiography needs of different parts.

3. With workstations international professional and state-of-the-art medical image processing technology, the English operation interface and the DR image processing function.

4. With high resolution professional medical display, high resolution, offer excellent image quality.

5. Using a Gigabit Ethernet connection with the DR detector, safe and efficient image acquisition; international Dicom3.0 standard interface for easy linking into the PACS system, transfer printing.

6. Independent research and development 60 kHz high-power high-frequency high-voltage generator, achieve 1ms ultra short exposure time, superior performance, world-class.

7. With KV, mAs two button system, kV, mA, s three-button system and AEC automatic exposure the three photography mode, can choose to better meet the professional requirements of different users.

8. Human graphical user interface, true color touch LCD screen, digital intelligent control system, makes operation is simple and convenient.

9. Have a multi-site, multi-position, multi-shape adults, children and other characteristics of the human body photography parameter settings, users can freely modify and storage easier.

10. With multiple automatic protection and fault code hint feature, maintenance more convenient.

11. Independent research and development, production of the new all-electric U-arm main frame, a wide range of lifting, rotating, meet standing and supine multi-site photography requirements.

12. Mechanical movement with automatic digital control drive technology, high-quality gear motor, stable performance, a key in place, accurate, reliable

13. Have three mechanical motion controls: close table touch screen, hand-held remote control and remote touch screen control in the workstation, quick and flexible operation.