CN-3128 3 Part Differential Auto Hematology Analyzer

Function: Automated WBC 3-Part
Parameters: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, LYM%, LYM#, GRAN%, MID%, MID#, PDW, MPV, PCT, RCDW, LCDW, RDW, P-LCR and WBC, RBC, PLT three histograms.
Principal: Electronic impedance, SFT method for hemoglobin
Throughput: ≥60T/H
Analysis Mode: Optional venous blood, anticoagulant blood and prediluted blood
Display: 8 inch TFT LCD (Optional Touch Screen)
Input Mode: Standard mouse and keyboard. Optional bar code reader
Print Mode: Internal high-speed thermal printer. Optional connection with specified external printer. English printouts
Report Format: Many kinds of report format (not less than 8 kinds)
Reagents System: Open reagent system. No cyanogen reagents. Provide original reagents.
Connection Port: USB, RS-232, network interface, LPT
Dimension: 345mm×245mm×330mm
Weight: 12Kg

Unique Functions

Real portable instrument(only 12Kg)

Precise & Reliable, Compact

Economical

Integrated Hydraulic design uses less reagents for testing. Reduce the cost for the users.

Fast & Convenient

Fast test, 60T/H, English operation interface, optional touch screen

1. Simple Operation  Low Consumption

Sample volume venous blood 9.6µL, capillary blood 20µL.

Remained reagent volume detected and reminder the operator.

Connect external printer as mini matrix printer, ink jet, stylus printer and laser printer.

Each kind data transmitted to external computer by RS232 port.


1633677570(1).jpg 

 

2. Advanced Design   Stable Performance

Automatic sleep and wake up, saving energy. The sampling needle be automatically back and out while stand by and wake up. It protects safe sampling and avoids contamination caused by long time exposure.

Large quantity test results storage, at least 400 thousand test results with comprehensive information. Extended SD memory supported.

Many reference value ranges (children, adult and the aged). The appropriate reference value range could be automatically selected according to the inputted age and sex.


3. Accurate Analysis    Perfect Quality

Analysis mode includes venous blood, capillary blood and prediluted.

Quality control mode of L-J, X-B and X-r. Westguard quality control regulation.

Manual and automatic calibration available. Fresh blood calibration available also.

Furnished with original reagents. Conform to the demand of International Standard Traceable System.

1633677587(1).jpg 

 

4. Convenient Maintenance   Safety & Eco-protection

Automatic & Intelligent function of diagnosis and maintenance; the log sheet for maintenance and malfunction could be established automatically.

Soak, back & forth flush, high pressure burning block-clearing.

Leaf door construct for convenient maintenance.


1633677602(1).jpg 

 

1. Automatic tittle sampling.

2. Standby Interface

3. Many kinds of QC mode.

4. Advanced malfunction diagnosis.

 

Technical Specifications:

Function: Automated WBC 3-Part

Parameters: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, LYM%, LYM#, GRAN%, MID%, MID#, PDW, MPV, PCT, RCDW, LCDW, RDW, P-LCR and WBC, RBC, PLT three histograms.

Principal: Electronic impedance, SFT method for hemoglobin

Throughput: ≥60T/H

Analysis Mode: Optional venous blood, anticoagulant blood and prediluted blood

Sample Volume: Anticoagulant whole blood ≤9.6µL, Anticoagulant capillary blood ≤9.6µL, prediluted capillary blood ≤20µL, the sample volume for repeating two times testing and avoiding second sampling

Working Mode: Automatic sampling, detecting automatic testing, furnished with dilutor, no need diluting outside. Automatic dispensing lyse and making second diluting automatically

Block-clearing: Soak and washing back and forth, high pressure burning. Boast the function of monitoring incomplete blockage

Alarm: Automated system diagnosis, self testing, fault alarm and reagent shortage alarm

Automated Maintenance: Automated washing during power on and power off, reducing the blockage rate

Standby Protection: 24 hours switch on, automatic sleep and wake up function

Storage: Large quantity test results storage, at least 400 thousand test results with comprehensive information. Extended SD memory supported.

Control Mode: Quality control mode of L-J, X-B and X-r. Westguard quality control regulation

Calibration Mode: Manual and automatic calibration available. Fresh blood calibration available also.

Reference Value Setting: Many reference value ranges (children, adult and the aged). The appropriate reference value range could be automatically selected according to the inputted age and sex.

Discriminator Function: Float and fix discriminator. Manual adjust available

Display: 8 inch TFT LCD (Optional Touch Screen)

Input Mode: Standard mouse and keyboard. Optional bar code reader

Print Mode: Internal high-speed thermal printer. Optional connection with specified external printer. English printouts

Report Format: Many kinds of report format (not less than 8 kinds)

Reagents System: Open reagent system. No cyanogen reagents. Provide original reagents.

Connection Port: USB, RS-232, network interface, LPT

Dimension: 345mm×245mm×330mm

Weight: 12Kg

 

REAGENT

Ordinary Package of CN-3128 (Suggest to send by AIR), One Set including below:

CODE

DESCRIPTION

SPEC

30201

Diluents

5L

30202

Lyse

400ml

30203

Detergent

500ml

 

Big Package of CN-3128 (Suggest to send by SEA), One Set including below:

CODE

DESCRIPTION

SPEC

30201

Diluents

20L

30202

Lyse

1L

30203

Detergent

5L

30204

Enzyme cleaner

100ml