CN-8000B Defibrillator with Monitor (Biphasic Technology)

Technical Specifications
Defibrillator
(1) Defibrillator type Manual, Synchronized, Asynchronized,
(2) Out put waveform Biphasic technology
(3) Energy accuracy ∠+1%
(4) Energy selection 0, 20, 50,100,160,250,300,360 joule (nominal at a resistance of 50)
(5) Charging time Maximum 8 seconds to 360 Joules
(6) Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated)

Technical Specifications

Defibrillator

(1) Defibrillator type   Manual, Synchronized, Asynchronized,    

(2) Out put waveform   Biphasic technology                                                                             

(3) Energy accuracy   +1%

(4)  Energy selection  0, 20, 50,100,160,250,300,360 joule (nominal at a resistance of 50)

(5) Charging time       Maximum 8 seconds to 360 Joules

(6)  Standard Adult/Pediatric Paddles   Reusable external adult paddles (pediatric paddles integrated)

            

Power requirements

(a) AC Power supply  110V, 60 Hz /220V, 50 Hz   

(b) Vehicle Voltage           DC 12V

 

Internal Battery Backup

(1) Battery type      Rechargeable lead-acid battery

(2) Charging time      Time-Minimum of 4 hours for full charging     

(3) Battery charging      During AC Power Supply operation of the device.

(4) Charging /Low Battery Indication      Red LED                 

(5) Battery Capacity        100% of the battery will provide 120 minutes of monitoring; and 30 discharges at 360 joules.

 

Display

LED Dimensions 10’diagonal

Type High resolution true-color graphic LED

 

ECG

ECG lead: , , , AVR, AVL, AVF, V1V6, GND

S-T segment analysis: -2.02.0mv

Arrhythmia analysis: yes

Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation

 

Respiration

Measurement method: Thoracic impedance

 

NIBP

Working mode: Manual/Automatic/stat (5 minutes)
Method: Automatic oscillation
Cuff type: standard Adult; optional Pediatric/Neonatal

 

Temperature

Measurement range 20~45 

Resolution 0.1

 

Pulse Oximetry (SPO2)

Display :SPO2 value, pulse histogram, waveform, Pulse

Range: 0~99%for adult, pediatric and neonatal patients

Probe :Standard adult finger clip

Optional pediatric Y-type clip and neonatal wrap

 

Pulse range
Pulse range: 0-255bpm

 

Standard Configuration

 ECG/ RESP, /SPO2, /TEMP,/PR,/NIBP/DEFIBRILLATOR

 

Optional Parameter

Built-in Printer

 

Physical Characteristics

Main unit: Desktop

Dimensions: L410xW360xH260 mm

Weight: 13kg


INQUIRY

CATEGORIES

CONTACT US

Contact: Katrina Yao

Phone: +0086 18255652021

Tel: +86 0556-5222292

Email: chuangen.medical@aliyun.com

Add: Area C, Huamao 1958 Project, No.80, South Fangzhi Road, Daguan District, Anqing, Anhui, China.