Welcome: chuangen medical
Language: Chinese ∷  English
chuangen.medical@aliyun.com +86 0556-5222292

CN-1109 Microplate Reader / Elisa Reader

Microplate types: 96-well plate(U,V,or plat-bottom)
Wavelength:405nm,450nm,492nm,630nm,4 free positions for additional filters
wavelength accuracy < 2nm
Reading range:0.000-4.000 Abs
Measurement range: 0.000-3.000Abs
Light source:Tungsten Halogen,12V/20W,>2000 hours
Measuring system:8-channel optical system
Test mode : End-point, kinetic, Multi-wave analysis
Resolution <1% or ±0.001Abs
Stability: <±0.005Abs/10min
Well Coincidence:≤0.015A
Linearity: r > 0.999
Repeatability: < 0.3%
Reading speed : 5s single wavelength , 10s double wavelength
QC:Westguard Multi-rule,automated QC alert.
Self-Checking function : Self-checking and calibration function.
CPU: High-speed CPU
Printer: External jet printer, multi-form patient report.
Interface :RS232 interface,USB, and PC connection.
Power supply: 220VAC 15% or 110VAC 15%50-60Hz 100w
Work environment: Temp 5℃—40℃;Humi ≤85%;
Machine Dimension: : 43CM*34CM*16CM
Weight : 9 KG

Feature

● Windows operation interface, figure button, mouse operation 

● 96-well plate, multiple tests in the single plate.

Arrangement of Test item in micro-plate can be store and re-use

● Parameter can be modified and stored

Plate shaking, speed and time adjustable

● Open system, test item and parameters can be added or modified.

● Large storage for 1000 test item and 1,000,000 results

● 10.4 inch color LCD

● Printing comprehensive report,include hosiptal and patient information and test results

Specifications 

Microplate types: 96-well plate(U,V,or plat-bottom)

Wavelength:405nm,450nm,492nm,630nm,4 free positions for additional filters

wavelength accuracy < 2nm

Reading range:0.000-4.000 Abs

Measurement range: 0.000-3.000Abs

Light source:Tungsten Halogen,12V/20W,>2000 hours

Measuring system:8-channel optical system

Test mode : End-point, kinetic, Multi-wave analysis

Resolution <1% or ±0.001Abs

Stability: <±0.005Abs/10min

Well Coincidence:≤0.015A

Linearity: r > 0.999

Repeatability: < 0.3%

Reading speed : 5s single wavelength , 10s double wavelength

QC:Westguard Multi-rule,automated QC alert.

Self-Checking function : Self-checking and calibration function.

CPU: High-speed CPU

Printer: External jet printer, multi-form patient report.

Interface :RS232 interface,USB, and PC connection.

Power supply: 220VAC 15% or 110VAC 15%50-60Hz 100w

Work environment: Temp 5—40Humi ≤85%;

Machine Dimension: : 43CM*34CM*16CM

Weight : 9 KG


INQUIRY

CATEGORIES

CONTACT US

Contact: Katrina Yao

Phone: +0086 18255652021

Tel: +86 0556-5222292

Email: chuangen.medical@aliyun.com

Add: Area C, Huamao 1958 Project, No.80, South Fangzhi Road, Daguan District, Anqing, Anhui, China.