Welcome: chuangen medical
Language: Chinese ∷  English
chuangen.medical@aliyun.com +86 0556-5222292

CN-SY-100A AccuFusion Infusion Pump

Advangtage
Numeric setting and operation for more friendly use
Semi-Squeeze peristaltic pump working principle to ensure best elesticity of LV. sets for best accuracy.
Original technology and patent for pressure detection to ensure safer and more accurate infusion.
Multiple monitoring of technology for unique security design to achieve best safety of infusion.
Different infusion mode for better clinical compatibility.
Event log with more than 1000 pieces of infusion information, helping clinical analyzation to provide good care and treatment.

Advangtage

Numeric setting and operation for more friendly use

Semi-Squeeze peristaltic pump working principle to ensure best elesticity of LV. sets for best accuracy.

Original technology and patent for pressure detection to ensure safer and more accurate infusion.

Multiple monitoring of technology for unique security design to achieve best safety of infusion.

Different infusion mode for better clinical compatibility.

Event log with more than 1000 pieces of infusion information, helping clinical analyzation to provide good care and treatment.




IS39GU$(5QRMB4VD4O5YATM.png
E8ALW9V~O40SJHCH}~4JPEK.png


 

Technical Specifications


Model No.

Parameters


CN-SY-100

Infusion Principle


Fingertip Peristaltic Pump

I.V.Set Compatibility


All brands,special or quality PVC,TPE infusion sets with an external diameter of 3.4mm ~ 4.5mm

Range of Flow Rate


1 ~1200ml/h

Infusion Rate Step By


Increments at 0.1 ml/h

Infusion Mode


Flow-rate mode,Time mode, Drop mode, Body weight mode

Purge/Bolus Rate


Set between (50.0 ~ 800.0)ml/h for 0.1 ml/h step

Time Preset


1s*99h59m59s), step by 1s.

Volume Range


0.1-9999.99ml

Drop Range


1-300 d/min, step by 1 drop



Drug amount range 0.1 ~ 999.9 mg, step by 0.1mg

Body Weight Mode


Dosage range 0.01 ~ 999.99 mg/kg/h, step by 0.01 mg/kg/h



Weight range 1 ~ 300 kg, step by0.1 Kg

Accuracy


±5%

Air-in-line Detection


Ultrasonic wave, and 5 grades for sensitivity adjustments

Occlusion Pressure


For up stream occlusion, within -20kPa ~ -60kPa, and 8 grades for sensitivity adjustments


Fordown stream occlusion, within 20kPa~ 140kPa, and 8 grades for sensitivity adjustments

Visible & Audible Alarms


Air in line, Upstream Occlusion,Down Stream Occlusion, Door open, VTBI completion, Low battery,Drop error.Pause overtime.MPU error,Pressure detect module error,Motor malfunction,Low battery, Battery error, A.C Disconnection

Event Logo


1000 event list including( Infusion start/stop time,flow rate, alarms etc)

K.V.O rate


1ml/h~5ml/h, defaul value 1ml/h, can be programmed by userstepby 0.1

Internal Battery


Ni-Mh rechargeable battery, 12V/800mAh, more than 3 hours working back up

Power


AC:100V-240V 50HZ/60HZ

Power Consumption


<20VA

Working Environment


Temperature: +5-+40°C ;Atmospheric pressure: 20%-90%; Relative Humidity:700hPa-1060hPa

Classification


Class I,Type CF, IPX4

Dimension & Weight


130mm(L)x118mm(W)x206mm(H); 1.4Kg

Optional Function


Drop Sensor, WIFI, Heating Function